> For the complete documentation index, see [llms.txt](https://enercalc.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://enercalc.com/docs/sel-user-manual/calculation-modules/linked-loads/edit-link-settings/link-settings-for-general-foot.md).

# Link Settings for General Footings

How to configure link settings that transfer beam or column reactions onto an active General Footing calculation.

When linking beam support reactions to the **active** general footing calculation, reactions are linked as pure vertical loads acting at the center of the pedestal. Transfer of beam end moment reactions to the footing is **not** currently supported:

![](https://3283832020-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FiBJmBoewuy4ZcBC7RF3m%2Fuploads%2Fgit-blob-608ccdfa0f018f1ea3de629925be6eea5d0035ea%2FLinked%20Loads%20-%20Linking%20Settings%20-%20Beam%20to%20General%20Footing.png?alt=media)

When linking column base reactions to the **active** general footing calculation, there are three main components to this portion of the window:

![](https://3283832020-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FiBJmBoewuy4ZcBC7RF3m%2Fuploads%2Fgit-blob-10bd9c1d3ae8aa99518e021522a4070402daa735%2FLinked%20Loads%20-%20Linking%20Settings%20-%20Column%20to%20General%20Footing.png?alt=media)

**1) Align Column +X to:** Start by selecting how the column should be oriented relative to the General Footing. Since columns and footings use different local axis conventions, it’s important to define the column’s orientation accurately.

{% hint style="info" %}
NOTE:
{% endhint %}

* Reactions are always applied equal and opposite from the upstream member. For example, if the upstream column calculation reports a +Vxx reaction, this will impose a -Vxx reaction on the footing.
* Additionally, by specifying how the column’s local +X axis aligns with the footing’s local +X axis, the program can correctly interpret the direction of all shears and moments as they relate to the footing.
* **All required sign conversions are handled automatically** and will account for differences in local axis conventions.

**2) Info button:** Click this button to view a graphic that illustrates how different column orientations and their reactions apply to the supporting footing.

By changing tabs at the top of the window, you can view the various options for column orientation. For convenience, you can also click **Link Load with Displayed Orientation** at the bottom of the window to apply the reactions using the current view.

![](https://3283832020-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FiBJmBoewuy4ZcBC7RF3m%2Fuploads%2Fgit-blob-445d8f12b8b4e3a69d8e4c72d50fb97c3bf2c0b1%2FLinked%20Loads%20-%20Linking%20Settings%20-%20General%20Footing%20-%20Info.png?alt=media)

**3) Add the Linked Load:** Once you've defined the orientation settings, click **Link Load** to add the linked reactions.

{% hint style="info" %}
NOTE: The General Footing module supports only one linked load at a time. If the Link Load button is disabled, it usually means a linked load already exists. In that case, select the existing load from the [Linked Reactions Table](https://enercalc.com/docs/sel-user-manual/calculation-modules/linked-loads/linked-reactions-table/link-reactions-table-for-gener.md) and remove it before adding a new one.
{% endhint %}

Once you've click the **Link Load** button, you will see that the new linked load has been added to the [Linked Reactions Table](https://enercalc.com/docs/sel-user-manual/calculation-modules/linked-loads/linked-reactions-table.md).


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://enercalc.com/docs/sel-user-manual/calculation-modules/linked-loads/edit-link-settings/link-settings-for-general-foot.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.