> For the complete documentation index, see [llms.txt](https://enercalc.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://enercalc.com/docs/sel-user-manual/calculation-modules/linked-loads/edit-link-settings/link-settings-for-beams.md).

# Link Settings for Beams

How to set the quantity, location, and spacing when linking support reactions to the active beam calculation.

When linking reactions to the **active** beam calculation, there are three main components to this portion of the window:

![](https://3283832020-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FiBJmBoewuy4ZcBC7RF3m%2Fuploads%2Fgit-blob-abf94da09186c05b628961062ef1dddfec238754%2FLinked%20Loads%20-%20Linking%20Settings%20-%20Beam.jpg?alt=media)

**1) Linked Load Quantity:** Start by specifying how many times the support reaction should occur at each location by updating the **"Apply Linked Load \_\_\_ times at ea. location"** input. This can be useful when a given support reaction occurs multiple times at a single location on the active beam (for example, when an infill beam frames into each side of a girder).

**2) Linked Load Location:** Next, specify where the support reaction occurs on the current beam. The available options are:

**Specify:** Specify an exact location for the load.

* Selecting "Beam" measures the dimension from the far left end of the beam regardless of support conditions. The resulting linked load will always be at this fixed dimension even if the underlying span lengths and quantities change. This dimensional value is restricted to the maximum length of the entire beam. If span length adjustments cause the load to extend beyond the beam's end, it will automatically reposition to the far right end of the beam.
* Selecting "Selected Span" measures the dimension from the left end of the currently selected span. The resulting linked load will always correspond to the span index of the selected span. For example, if there are two spans and the second span is selected, the linked load will apply to the second span (span index = 2). As long as there are at least two spans, the linked load will consistently be associated with span index 2, regardless of any spans that are added or deleted in the future.

**Midspan, 1/3 Pts, & 1/4 Pts:** Automatically place the load at the midspan, one-third points, or one-quarter points. These locations are relative to the span length and will adjust automatically if the span lengths change.

* Selecting "All Spans" will apply the linked load to all spans within the currently active beam calculation, including any new spans which may be created in the future.
* Selecting "Selected Span" will apply the linked load to the span index of the currently selected span. As described above, the resulting linked load will always correspond to the span index of the selected span regardless of any spans that are added or deleted in the future.

**Spacing:** Specify repetitive loads by defining a start point and a spacing. The first load will be placed at the "From" dimension, and additional loads will be repeated at the defined spacing throughout the entire length of the beam.

**3) Add the Linked Load:** Once you have defined the settings for the linked load, click the **Link Load** button.

Once you've click the **Link Load** button, you will see that the new linked load has been added to the [Linked Reactions Table](https://enercalc.com/docs/sel-user-manual/calculation-modules/linked-loads/linked-reactions-table.md).


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://enercalc.com/docs/sel-user-manual/calculation-modules/linked-loads/edit-link-settings/link-settings-for-beams.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.