Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Design Parameters Tab

How to enter soil, embedment, base pad, slope, and factor-of-safety inputs for segmental retaining wall design.

Retained Height: Displays the retained height based on block coursing and geometry entered on the Block & Geogrid tab.

Embedment: Depth below grade (on the low side) to top of setting pad. Usually one block course or 1’-0”.

Base Pad Depth: Thickness of the base pad.

Soil Density, Exterior (in-situ): Enter the density of the native soil beyond the backfill zone and under the base.

Soil Density, Interior (backfill): Enter the density of the backfill material (typically granular soil or gravel).

Soil Phi, Exterior (in-situ): Enter the angle of internal friction of in-situ soil.

Soil Phi, Interior (backfill): Enter the angle of internal friction of the backfill soil.

Allowable Soil Bearing Pressure: Enter the allowable soil bearing pressure.

Backfill Slope: Select the backfill slope from the drop-down list box.

Minimum Acceptable Factors of Safety: Specify the minimum acceptable factors of safety for each of the different failure modes, or click the reset button to easily reset all values to defaults as per NCMA Table 5-2.

Last updated

Was this helpful?