> For the complete documentation index, see [llms.txt](https://enercalc.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://enercalc.com/docs/sel-user-manual/calculation-modules/earth-retention/cantilevered-and-restrained-re/st-stem-tab/st-cantilevered-wall/rt-stress-ratio.md).

# Summary Section of Stem Tab

Describes stem design summary results, including interaction ratio, moments, shear, and rebar lap and embedment lengths.

The **Stem** tab summary shows the stem design results.

### Design Results

**Interaction Ratio** shows the demand-capacity ratio (D/C ratio). The ratio must not exceed 1.0.

For masonry using ASD, the program calculates $$f\_a/F\_a + f\_b/F\_b$$.

For concrete and masonry using LRFD, the program calculates $$M\_\mathrm{actual}/M\_\mathrm{allowable}$$.

The weight of the stem is included only when there is added axial load. For masonry stems, $$F\_a$$ is calculated by considering the wall unsupported with $$K = 2.0$$. Even a very small axial load activates the unsupported-height and slenderness calculation for masonry stems. We suggest that you don't enter an axial load unless it is significant, such as greater than 3,000 plf.

**Actual Moment** is the maximum moment from lateral pressures and applied loads above the entered **Design Height**. For concrete, the program factors soil pressures and loads using the default load factors when evaluating moment and shear.

**Allowable Moment** is the moment capacity. For masonry designed using ASD, it is the allowable-stress design moment capacity. For concrete and masonry designed using LRFD, it is the strength design moment capacity. For concrete strength design, equilibrium at the prescribed strain limits controls the maximum reinforcing-steel percentage.

**Total Force** is the total lateral force from loads above the entered **Check Design at Height**. The program factors this force for concrete and LRFD masonry. It does not factor forces used for overturning, sliding, or soil-pressure calculations.

**Actual Shear:** For masonry stems, the program calculates shear stress as $$V/A\_n$$. For concrete stems, it calculates shear stress as $$V/(12\text{ in.} \times d)$$.

### Allowable Shear

#### Masonry Stems Using ASD

For masonry stems using ASD, the program calculates allowable shear stress under TMS 402-16 Eq. 8-26:

$$
F\_{vm}=\frac{1}{2}\left\[ \left(4.0-1.75\left(\frac{M}{Vd\_v}\right)\right)\sqrt{f'\_m}\right] + 0.25\frac{P}{A\_n}\geq0
$$

Where:

* $$F\_{vm}$$ is the masonry shear stress.
* $$M$$ is the applied moment.
* $$V$$ is the applied shear force.
* $$d\_v$$ is the effective shear depth.
* $$f'\_m$$ is the specified masonry compressive strength.
* $$P$$ is the axial load.
* $$A\_n$$ is the net cross-sectional area.

The ratio $$M/(Vd\_v)$$ need not exceed 1.0. Since reinforcing steel provides no shear-strength contribution in a retaining wall, and the stem is not a partially grouted shear wall, TMS 402-16 Eq. 8-22 reduces to $$F\_v = F\_{vm}$$.

The program limits $$F\_v$$ to $$F\_{v,\mathrm{max}}$$:

1. $$F\_{v,\mathrm{max}}\leq 3\sqrt{f'\_m}$$ when $$M/(Vd\_v)\leq0.25$$.
2. $$F\_{v,\mathrm{max}}\leq 2\sqrt{f'\_m}$$ when $$M/(Vd\_v)\geq1.0$$.
3. It linearly interpolates $$F\_{v,\mathrm{max}}$$ when $$M/(Vd\_v)$$ is from 0.25 to 1.0.

#### Masonry Stems Using LRFD

For masonry stems using LRFD, the program calculates nominal shear strength under TMS 402-16 Eq. 9-20:

$$
v\_{nm}=\left\[4.0-1.75\left(\frac{M\_u}{V\_ud\_v}\right)\right]\sqrt{f'\_m} + 0.25\frac{P\_u}{A\_n}\geq0
$$

Where:

* $$v\_{nm}$$ is the nominal masonry shear strength.
* $$M\_u$$ is the factored moment.
* $$V\_u$$ is the factored shear force.
* $$d\_v$$ is the effective shear depth.
* $$f'\_m$$ is the specified masonry compressive strength.
* $$P\_u$$ is the factored axial load.
* $$A\_n$$ is the net cross-sectional area.

The ratio $$M\_u/(V\_ud\_v)$$ need not exceed 1.0. Since reinforcing steel provides no shear-strength contribution in a retaining wall, and the stem is not a partially grouted shear wall, TMS 402-16 Eq. 9-17 reduces to $$v\_n = v\_{nm}$$.

The program limits $$v\_n$$ to $$v\_{n,\mathrm{max}}$$:

1. $$v\_{n,\mathrm{max}}\leq 6\sqrt{f'\_m}$$ when $$M\_u/(V\_ud\_v)\leq0.25$$.
2. $$v\_{n,\mathrm{max}}\leq 4\sqrt{f'\_m}$$ when $$M\_u/(V\_ud\_v)\geq1.0$$.
3. It linearly interpolates $$v\_{n,\mathrm{max}}$$ when $$M\_u/(V\_ud\_v)$$ is from 0.25 to 1.0.

#### Concrete Stems

For concrete stems designed per ACI 318-14 and earlier, or ACI 318-25 and later with [Use simplified Vc equation (Section 13.3.6.1.1)](https://enercalc.com/docs/sel-user-manual/calculation-modules/earth-retention/cantilevered-and-restrained-re/st-stem-tab/st-cantilevered-wall.md#design-options) enabled, the nominal shear strength is calculated as follows:

$$
\phi v\_n = \phi 2 \lambda \sqrt{f'\_c}, \text{ where } \phi = 0.75
$$

For concrete stems designed per ACI 318-19, or ACI 318-25 and later with [Use simplified Vc equation (Section 13.3.6.1.1)](https://enercalc.com/docs/sel-user-manual/calculation-modules/earth-retention/cantilevered-and-restrained-re/st-stem-tab/st-cantilevered-wall.md#design-options) disabled, the nominal shear strength follows the one-way shear provisions of §22.5 and Table 22.5.5.1, referenced by §13.3.6.1 and §7.5.3.1:

$$
\phi v\_n = \phi 8 \lambda\_s \lambda \rho\_w^{1/3} \sqrt{f'\_c}, \text{ where } \phi = 0.75
$$

{% hint style="info" %}
**NOTE:** The one-way shear capacity assumes no transverse reinforcement in the stem. Therefore, $$A\_v < A\_{v,\mathrm{min}}$$, and equations (a) and (b) from Table 22.5.5.1 aren't applicable.
{% endhint %}

This value is also subject to additional limits per §22.5.5.1.1:

* Lower bound: $$\phi \lambda \sqrt{f'\_c}$$ for ACI 318-25 and later only.
* Upper bound: $$\phi 5 \lambda \sqrt{f'\_c}$$.

### Rebar Lap and Embedment Lengths

The **Rebar Lap & Embedment Lengths** table summarizes lap splice and development lengths. On the **Stem Design Values** tab, select the associated button to open the table.

#### Straight Development Length of Rebar in Concrete

Per ACI 318-14 Eq. 25.4.2.3a or ACI 318-19 Eq. 25.4.2.4a:

$$
\ell\_d=\frac{3}{40}\left(\frac{f\_y}{\sqrt{f'\_c}}\right)\left(\frac{\psi\_s}{2.5}\right)\left(\frac{\text{bar size}}{8}\right)\geq12\text{ in.}
$$

Where:

* $$f\_y$$ is the rebar yield stress.
* $$f'\_c$$ is the concrete compressive strength.
* $$\psi\_s$$ is 0.8 for No. 6 bars and smaller or 1.0 for No. 7 bars and larger.

{% hint style="info" %}
**NOTE:** The calculation assumes the applicable bar location, clear cover, spacing, transverse reinforcement, and epoxy-coating factors.
{% endhint %}

#### Lap Splice Length of Rebar in Concrete

For all supported ACI editions, the lap splice length is:

$$
\ell\_s=1.3\ell\_d\geq12\text{ in.}
$$

#### Hooked Embedment of Rebar in Concrete

For hooked embedment in concrete, the program applies the following equations.

For ACI 318-14:

$$
\ell\_{dh}=\left(\frac{f\_y\psi\_e\psi\_c\psi\_r}{50\lambda\sqrt{f'\_c}}\right)d\_b\geq\max(8d\_b, 6\text{ in.})
$$

Where:

* $$f\_y$$ is the rebar yield stress for the bottom stem segment.
* $$\psi\_e$$ is the epoxy factor, set to 1.0.
* $$\psi\_c$$ is the user-specified cover factor, 0.7 or 1.0.
* $$\psi\_r$$ is the user-specified confining-reinforcement factor, 0.8 or 1.0.
* $$\lambda$$ is the lightweight factor, set to 1.0.
* $$f'\_c$$ is the footing concrete compressive strength.
* $$d\_b$$ is the rebar diameter for the bottom stem segment.

For ACI 318-19:

$$
\ell\_{dh}=\left(\frac{f\_y\psi\_e\psi\_r\psi\_o\psi\_c}{55\lambda\sqrt{f'\_c}}\right)d\_b^{1.5}\geq\max(8d\_b, 6\text{ in.})
$$

Where:

* $$f\_y$$ is the rebar yield stress for the bottom stem segment.
* $$\psi\_e$$ is the epoxy factor, set to 1.0.
* $$\psi\_r$$ is the user-specified confining-reinforcement factor, 1.0 or 1.6.
* $$\psi\_o$$ is the user-specified location factor, 1.0 or 1.25.
* $$\psi\_c$$ is the concrete-strength factor, the lesser of $$f'\_c/15{,}000+0.6$$ and 1.0.
* $$\lambda$$ is the lightweight factor, set to 1.0.
* $$f'\_c$$ is the footing concrete compressive strength.
* $$d\_b$$ is the rebar diameter for the bottom stem segment.

For ACI 318-25:

$$
\ell\_{dh}=\left(\frac{f\_y\psi\_e\psi\_s\psi\_{cc}\psi\_r}{50\lambda\sqrt{f'\_c}}\right)d\_b\geq\max(8d\_b, 6\text{ in.})
$$

Where:

* $$f\_y$$ is the rebar yield stress for the bottom stem segment.
* $$\psi\_e$$ is the epoxy factor, set to 1.0.
* $$\psi\_s$$ is the size factor. It is 1.0 for No. 9 bars and smaller, 1.15 for No. 10 and No. 11 bars, 1.3 for No. 14 bars, and 1.5 for No. 18 bars.
* $$\psi\_{cc}$$ is the user-specified cover factor, 0.7 or 1.0.
* $$\psi\_r$$ is the user-specified confining-reinforcement factor, 0.8 or 1.0.
* $$\lambda$$ is the lightweight factor, set to 1.0.
* $$f'\_c$$ is the footing concrete compressive strength.
* $$d\_b$$ is the rebar diameter for the bottom stem segment.

{% hint style="info" %}
**NOTE:** §25.4.10 does not permit reducing hooked development length by $$A\_{s,\mathrm{required}}/A\_{s,\mathrm{provided}}$$:
{% endhint %}

![](https://3283832020-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FiBJmBoewuy4ZcBC7RF3m%2Fuploads%2Fgit-blob-7be479cae428710dc0e880ebaeabaa175af2a855%2FExcess%20reinf%20factor%20not%20allowed.jpg?alt=media)

#### Development Length of Rebar in Masonry Designed by ASD

Applies to all referenced codes.

$$
\ell\_d=0.002\left(\frac{\text{bar size}}{8}\right)f\_s\geq12\text{ in.}
$$

Where:

* $$f\_s$$ is the actual rebar stress.

#### Lap Splice Length of Rebar in Masonry Designed by ASD

For masonry using ASD, the lap splice length is:

$$
\ell\_s=1.5\ell\_d\geq\max(12\text{ in.},40d\_b)
$$

#### Development Length of Rebar in Masonry Designed by LRFD

Applies to all referenced codes.

$$
\ell\_d=\frac{0.13\left(\frac{\text{bar size}}{8}\right)^2f\_y\gamma}{K\sqrt{f'\_m}}\geq12\text{ in.}
$$

Where:

* $$f\_y$$ is the rebar yield stress.
* $$\gamma$$ is the bar-size factor: 1.0 for No. 3 through No. 5 bars, 1.3 for No. 6 through No. 7 bars, and 1.5 for No. 8 through No. 9 bars.
* $$K$$ is the clear-cover factor: 1.5 for No. 3 through No. 5 bars and 2.0 for No. 6 through No. 9 bars.
* $$f'\_m$$ is the specified masonry compressive strength.

This equation is referenced directly from the IBC.

{% hint style="info" %}
**NOTE:** The program conservatively sets $$K$$ to the required clear cover for the selected rebar exposed to earth.
{% endhint %}

#### Lap Splice Length of Rebar in Masonry Designed by LRFD

For masonry using LRFD, the lap splice length is:

$$
\ell\_s=\ell\_d\geq12\text{ in.}
$$

The lap splice need not exceed $$72d\_b$$.

#### General Notes on Rebar Lap and Embedment Lengths

For concrete stems, the program assumes a Class B lap splice. The lap length equals 1.3 times the bar development length. It assumes normal-weight concrete and plain, non-epoxy-coated bars.

The program calculates concrete development lengths under the applicable ACI edition.

At the bottom **Design Height** only, where $$H\_t = 0.00$$, the table shows required hooked-bar embedment into the footing. It assumes a 90° bend and an extension of at least $$12d\_b$$.

The required footing thickness includes this embedment depth and your specified bar clearance, usually 3 in. The program shows a warning when the total exceeds the selected footing thickness.

If the bar extends straight down into a key, its embedment depth must equal the development length.

The program doesn't reduce embedment length by stress level unless you select **Reduce Hook Embedment by Percent Rebar Stress**.

The program never reduces lap splice lengths by the stress ratio. The referenced codes don't permit it.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://enercalc.com/docs/sel-user-manual/calculation-modules/earth-retention/cantilevered-and-restrained-re/st-stem-tab/st-cantilevered-wall/rt-stress-ratio.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.