> For the complete documentation index, see [llms.txt](https://enercalc.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://enercalc.com/docs/sel-user-manual/calculation-modules/earth-retention/cantilevered-and-restrained-re/lt-loads-tab/lt-seismic-loads.md).

# Seismic Loads

How to apply seismic earth pressure and stem self-weight loads to retaining walls using Mononobe-Okabe.

![](https://3283832020-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FiBJmBoewuy4ZcBC7RF3m%2Fuploads%2Fgit-blob-afe30b96d66f3cfe8115e7636df33c118a7f5287%2FClip16.jpg?alt=media)

You can choose to apply seismic force from lateral earth pressure and/or from wall self-weight.

**Seismic Lateral Earth Pressure**

This category is used to specify whether seismic lateral earth pressure is to be considered or not. If it is to be considered, the program offers the option of two different methods:

* Mononobe-Okabe/Seed-Whitman procedure, or
* Simplified procedure per Geotechnical report

**Mononobe-Okabe/Seed-Whitman Procedure**

By entering kh the program will calculate KAE and KA using the Mononobe-Okabe/Seed-Whitman equations for a yielding wall (cantilevered).

If it is a non-yielding wall (restrained) the added lateral force per square foot is computed using Fw = kh(density)(retained height), in psf. Common kh values range from 0.05 to 0.30, depending upon area seismicity. Some sources indicate that kh = SDS / 2.5, but jurisdictions and interpretations vary.

Both the static soil pressure component and the added seismic component will be displayed. The resultant seismic component is assumed to act at 0.6 x retained height. The seismic component is assumed to vary from an intensity of X at the bottom of footing to an intensity of 4X at the top of the retained height.

**Mononobe-Okabe/Seed-Whitman Methodology**

Two excellent references on the subject include [Basics of Retaining Wall Design](https://www.amazon.com/Basics-Retaining-Wall-Design-11th/dp/0976836475) 11th Edition by Hugh Brooks and *Seismic Earth Pressures on Deep Building Basements* by Lew, et al.

The program computes KAE (coefficient for combined active and earthquake forces) per the Coulomb formula, modified by Mononobe-Okabe/Seed-Whitman, to account for earthquake loading, where the term q is the angle whose tangent is the horizontal ground acceleration. (Note that if Kh = 0, q = 0, then KAE = KA.) Vertical acceleration is neglected, resulting in a more conservative KAE.

KAE = active earth pressure coefficient, static+seismic

![](https://3283832020-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FiBJmBoewuy4ZcBC7RF3m%2Fuploads%2Fgit-blob-4fb27a4ed3d7b3cde35a4eeb30b4f26e0ed261e9%2FM-O.jpg?alt=media)

Where q = tan-1 Kh, a = wall slope to horizontal (90 degrees for a vertical face), f = angle of internal friction, b = backfill slope, and d = wall friction angle.

For a vertical wall face and d assumed to be f/2, KAE becomes:

![](https://3283832020-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FiBJmBoewuy4ZcBC7RF3m%2Fuploads%2Fgit-blob-95250ae34bead9383d0a88fd38e949eef40760e0%2FKae%20for%20verical%20face.jpg?alt=media)

The values KAE and KA are displayed.

For the horizontal component, the forces are multiplied by cos δ (wall/soil interface angle).

Total force (active and seismic) = PAE = 0.5(g) KAE H2 where g = soil density and H = retained height.

Since the total force PAE consists of two components, static (PA, as previously computed for static forces) with triangular distribution and the earthquake (PAE - PA) with an inverted semi-triangular distribution with an assumed point of application at 0.60 x height, the combined (static and EQ) point of application is determined by

![](https://3283832020-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FiBJmBoewuy4ZcBC7RF3m%2Fuploads%2Fgit-blob-9ffd9822567cd229ac68906c6bbaaccde197eae1%2FHeight%20to%20combined%20static%20and%20seismic%20load.jpg?alt=media)

which is displayed as "Ht. to static + EQ point of appl."

Total base shear for both static force and added seismic force are displayed.

From *Seismic Earth Pressures on Deep Building Basements* by Lew, et al:

*If the Mononobe-Okabe analysis is used to determine the lateral seismic earth pressure, the lateral earth pressure should consist of the static active earth pressure and the seismic increment of earth pressure as discussed in the previous section. Presumably, the load factor of 1.6 in Eq. (8) would be applicable to the total earth pressure in this case. However, as noted above, a reduced load factor would be appropriate when considering the transitory nature of the seismic component and the low likelihood of the load maxima occurring simultaneously. Accordingly a lower load factor of 1.0 is proposed to be applied to the seismic increment component of earth pressure while the 1.6 load factor is applied to the static active pressure component. To facilitate such loading combination the geotechnical engineers would have to separate earth pressure components attributable to the active earth pressure condition and the seismic increment of earth pressure when using the M-O method*.

**For Cantilevered Retaining Wall Only:**

Other options include:

* Uniformly Distributed Load
* Triangular Distribution
* Inverted Triangular Distribution

**For Gravity Retaining Wall and Tapered Retaining Wall:**

**Simplified procedure per Geotechnical report**

Use this method if a geotechnical report specifies added seismic load as a factor multiplied by the retained height, such as X\*H, where X is the multiplier and H is the retained height, enter that multiplier here. Using this method, the seismic lateral force will be applied uniformly over the retained height. Since this is a factored force it will be reduced by 0.7 for use in sliding, overturning, and soil bearing calculations.

**For Cantilevered Retaining Wall, Gravity Retaining Wall and Tapered Retaining Wall:**

**Seismic due to stem Self-Weight**

If you indicate that you want the program to consider the seismic effect due to the self-weight of the stem, then you will specify a value for the factor Fp/Wp, which will be used to calculate a uniform seismic force in psf (Fp/Wp x (wall weight)). If the wall has multiple stem sections, each will be calculated separately and accumulated for the base shear and moment.

{% hint style="info" %}
**NOTE: The k\*\*\*\*h** **values entered are the** **design** **accelerations (not necessarily peak ground acceleration as may be given in a geotechnical report) and must be determined per procedures in the applicable code. The program then applies the appropriate Load Factors (1.0 for concrete design and 0.7 for serviceability checks).**
{% endhint %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://enercalc.com/docs/sel-user-manual/calculation-modules/earth-retention/cantilevered-and-restrained-re/lt-loads-tab/lt-seismic-loads.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.