Beam Stability (in Steel Column and Wood Column modules)

How to define column bracing for lateral-torsional buckling using the Beam Stability tab in steel and wood column modules.

Older versions of the column modules only had the Column Slenderness tab input to take some sort of guess as to what the bracing condition is for defining the lateral-torsional buckling strength. But there may be times where the bracing that is effective in resisting Euler (column) buckling would not be considered as effective in resisting lateral-torsional buckling. So the Beam Stability tab allows the user to more effectively define the column and the bracing for all of its failure modes.

The program evaluates the dimensions of the column member and offers three ways to define the unbraced length for flexure about the strong axis:

  • Lux = to enter the unbraced length directly.

  • Use overall column height to apply the full column height.

  • Fully braced for beam stability to indicate that lateral-torsional buckling isn't a consideration.

Selecting Use overall column height or Fully braced for beam stability disables the length entry.

Beam Stability tab as shown in the Wood Column module.
Beam Stability tab as shown in the Wood Column module

The tab for the weak axis simply indicates that lateral-torsional buckling is not a consideration when flexure occurs about the weak axis.