No more reduction in lap splice length or development length
Explains why lap splice and hooked embedment lengths cannot be reduced for excess reinforcing under ACI 318.
Why can't I select "Reduce lap splice by stress ratio" or "Reduce hooked embedment by As req'd / As provided" on the Stem tab?
ACI 318 does not permit reducing hooked embedment length using the As req'd / As provided ratio.
ACI 318 also prohibits reducing development length for excess reinforcing when calculating lap splice lengths. The restrictions depend on the selected design standard.
ACI 318-14
§25.5
Covers lap splices.
§25.5.1.4
Prohibits reducing development length for excess reinforcing when calculating lap splice lengths.
§25.4.3
Covers development of standard hooks in tension.
§25.4.10.2(a)
Prohibits reducing development length for excess reinforcing at noncontinuous supports.
§25.4.10.2(b)
Prohibits reducing development length for excess reinforcing where anchorage or development for fy is required.
ACI 318-19
§25.5
Covers lap splices.
§25.5.1.4
Prohibits reducing development length for excess reinforcing when calculating lap splice lengths.
§25.4.3
Covers development of standard hooks in tension.
§25.4.10.2(a)
Prohibits reducing development length for excess reinforcing at noncontinuous supports.
§25.4.10.2(b)
Prohibits reducing development length for excess reinforcing where anchorage or development for fy is required.
§25.4.10.2(d)
Prohibits reducing development length for excess reinforcing for hooked, headed, and mechanically anchored deformed reinforcement.
ACI 318-25
§25.5
Covers lap splices.
§25.5.1.4
Prohibits reducing development length for excess reinforcing when calculating lap splice lengths.
§25.4.3
Covers development of standard hooks in tension.
§25.4.10.2(a)
Prohibits reducing development length for excess reinforcing at noncontinuous supports.
§25.4.10.2(b)
Prohibits reducing development length for excess reinforcing where anchorage or development for fy is required.
§25.4.10.2(d)
Prohibits reducing development length for excess reinforcing for hooked, headed, and mechanically anchored deformed reinforcement.
Last updated
Was this helpful?