Rebar Placement and the Minimum Steel Calculation
How the General Footing module handles top and bottom rebar mats and the minimum reinforcing area calculation.
How does the module handle top and bottom rebar mats and the minimum reinforcing area calculation?
The General Footing module provides inputs for number and size of bars parallel to the x axis and parallel to the z axis for the bottom mat. If the Specify Top Reinforcing checkbox is selected, the module offers separate input fields to collect top rebar size, count, and clear cover.
When the footing is loaded with downward loads so that the tension is on the bottom, the resulting moment will be compared to the moment capacity assuming that the specified bars are located on the bottom of the footing. The program automatically incorporates the minimum reinforcing check from Section 7.6.1.1, and the commentary to Section 7.6.1.1 is clear that this amount applies independently to each tension surface.
If a footing happens to be subjected to net uplift so that tension occurs on the top, there is now an option to specify a top mat of reinforcing. When a top mat is specified, the resulting moment will be compared to the moment capacity assuming that the specified bars are located based on the specified top clear cover. Top mat results will also consider the minimum reinforcing requirements from Section 7.6.1.1.
The Footing Bending tabs still clearly indicate which surface is in tension, so you can quickly decide whether you need to specify a top mat or not.
Last updated
Was this helpful?